Proof of Concept using Lake Guard Oxy™ against Prymnesium sp.

May 31, 2017
White paper

Early PoC

Place: Maagan Michael, Israel

Date: May 2017

Background:

A treatment trial against Prymnesium sp. was conducted in Kibbutz Maagan Michael, Israel, in collaboration with the local Fish Health Laboratory.

We concluded that two consecutive treatments of 50-100 ppm of Lake Guard Oxy™ at time intervals of 3 hours apart was enough to eliminate Prymnesium sp. without adversely impacting other phytoplankton in the water.

While Prymnesium sp. disappeared from the water immediately after treatment, no significant change was detected for other water parameters, incl. specific conductivity, pH, temperature and Chlorophyll-a.

Moreover, fish were found susceptible to said H2O2 concentrations. This methodology is in agreement with work previously done by Prof. Aaron Kaplan at the Hebrew University and Assaf Vardi from the Weizmann Institute, Israel.

Prymnesium sp. was also treated with Lake Guard Blue™, as seen in the pictures below, at a concentration of 2 g/m.

Mountains above a clear lake

Contact us to make your waterbody safe

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
ISRAEL
Headquarters
16 HaMiktsoot Blvd,
Modi’in-Maccabim-Re’ut,
Israel, 7178096
global@bluegreenwatertech.com
+972 8 645 9666
USA
301 South Hills Village Ste LL200 #452
Pittsburgh, PA 15241
us@bluegreenwatertech.com
+1 866-269-2828
China
Room 1603, Sanlitun SOHO Building A,
North Workers Stadium Road, Chaoyang District, Beijing City, China
china@bluegreenwatertech.com
+86 1851 336 1851
South Africa
3 Villa Montina, Delmare Crescent, Mulbarton Road, Beverley AH, Sandton, Gauteng, South Africa, 2921
sa@bluegreenwatertech.com
+27 82 453 4924